Huawei NetEngine 8000 F1A¶
F1A-8H20Q
Портовая ёмкость:
- 28 x 1G / 10G
- 20 x 1G / 10G / 25G
- 8 x 40G / 50G / 100G / breakout 4x10G / breakout 4x25G
Спецификация на CR8B0BKP03C0:
| Item | Specification |
|---|---|
| Cabinet installation standards | IEC 19-inch |
| Dimensions without packaging (H x W x D) [mm(in.)] | 43.6 mm x 442 mm x 420 mm (1.72 in. x 17.4 in. x 16.54 in.) |
| Dimensions with packaging (H x W x D) [mm(in.)] | 175 mm x 550 mm x 650 mm (6.89 in. x 21.65 in. x 25.59 in.) |
| Chassis height [U] | 1 U |
| Weight without packaging (base configuration) [kg(lb)] | 6.3 kg (13.89 lb) |
| Weight without packaging (full configuration) [kg(lb)] | DC: 8.4 kg(18.52 lb)AC: 8.75 kg(19.29 lb) |
| Weight with packaging (full configuration) [kg(lb)] | DC: 13.58 kg(29.94 lb)AC: 13.75 kg(30.31 lb) |
| Typical power consumption [W] | 325 W |
| Typical heat dissipation [BTU/hour] | 1054.44 BTU/hour |
| MTBF [year] | DC: 25.52AC: 25.65 |
| MTTR [hour] | 0.5 hour |
| Availability | 0.99999 |
| CPU | 20-core 2.0 GHz |
| SDRAM | 16 GB |
| Storage | 4G NAND FLASH |
| Power supply mode | DC,AC/HVDC |
| Rated input voltage [V] | DC: -48 V/-60 VAC: 100 V to 240 V AC, support 240 V HVDC |
| Input voltage range [V] | DC: -40 V to -72 VAC: 90V to 290V |
| Maximum input current [A] | DC: 30 AAC: 8 A |
| Rated output power [W] | DC: 1000 WAC: 600 W |
| Maximum input cable diameter [mm²] | DC:4mm^2 (1-14 meters), 6mm^2 (15-21 meters), 10mm^2 (22-35 meters)AC:2.5mm^2 |
| Front-end circuit breaker/fuse [A] | DC:≥32AAC:≥10A |
| Heat dissipation | Air cooling |
| Airflow direction | Front to back: port-side intake |
| Noise at normal temperature (acoustic power) [dB(A)] | < 72 dB (meeting the ETSI 72 dBA standard) |
| Number of slots | 7 |
| Number of service board slots | 1 |
| Switching capacity | 2.4Tbit/s |
| Redundant power supply | 1+1 |
| Redundant fans | 3+1,Short-term running when a single fan becomes invalid at the ambient temperature of 40°C (104°F) |
| Long-term operating temperature [°C(°F)] | Port-side Intake:-5°C ~ 45°C(23°F to 113°F) |
| Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (86°F/hour) |
| Storage temperature [°C(°F)] | -40°C ~ 70°C(-40°F to 158°F) |
| Long-term operating relative humidity [RH] | 5% to 90% RH, non-condensing |
| Short-term operating relative humidity [RH] | 5% to 95% RH, non-condensing |
| Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | < 4000 m(< 13123.2 ft.) |
| Storage altitude [m(ft.)] | < 5000 m(< 16404.2 ft.) |
| RTU supported | Yes. 82402000: NetEngine 8000 F1A-8H20Q Fixed Port 100GE Upgrade RTU 82402001: NetEngine 8000 F1A-8H20Q Fixed Port 25GE Upgrade RTU 82402002: NetEngine 8000 F1A-8H20Q Fixed Port 10GE Upgrade RTU For details about how to use the RTU, see "Installation >License Usage Guide". |